<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Kelbaek, H.</title>
    <link>http://repub.eur.nl/res/aut/12120/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>Comparison of zotarolimus-eluting and everolimus-eluting coronary stents (Article)</title>
      <link>http://repub.eur.nl/res/pub/20630/</link>
      <pubDate>2010-07-01T00:00:00Z</pubDate>
      <description>BACKGROUND: New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS: In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS: At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P&lt;0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P = 0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (±SD) of in-stent stenosis (21.65±14.42% for zotarolimus vs. 19.76±14.64% for everolimus, P = 0.04 for noninferiority). In-stent late lumen loss was 0.27±0.43 mm in the zotarolimus-stent group versus 0.19±0.40 mm in the everolimusstent group (P = 0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS: At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria.</description>
    </item> <item>
      <title>Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13278/</link>
      <pubDate>2004-01-20T00:00:00Z</pubDate>
      <description>BACKGROUND: Polymer-controlled paclitaxel-eluting stents have shown a pronounced reduction in neointimal hyperplasia compared with bare metal stents (BMS). The aim of this substudy was to evaluate local arterial responses through the use of serial quantitative intravascular ultrasound (IVUS) analyses in the TAXUS II trial. METHODS AND RESULTS: TAXUS II was a randomized, double-blind study with 536 patients in 2 consecutive cohorts comparing slow-release (SR; 131 patients) and moderate-release (MR; 135 patients) paclitaxel-eluting stents with BMS (270 patients). This IVUS substudy included patients treated with one study stent who underwent serial IVUS examination after the procedure and at 6-month follow-up (BMS, 152 patients; SR, 81; MR, 81). The analyzed stented segment (15 mm) was divided into 5 subsegments in which mean vessel area (VA), stent area (SA), lumen area (LA), intrastent neointimal hyperplasia area (NIHA), and peristent area (VA-SA) were measured. NIHA was significantly reduced in SR (0.7+/-0.9 mm2, P&lt;0.001) and MR (0.6+/-0.8 mm2, P&lt;0.001) compared with BMS (1.9+/-1.5 mm2), with no differences between the two paclitaxel-eluting release formulations. Longitudinal distribution of neointimal hyperplasia throughout the paclitaxel-eluting stent was uniform. Neointimal growth was independent of peristent area at postprocedure examination in all groups. There were progressive increases in peristent area from BMS to SR to MR (0.5+/-1.7, 1.0+/-1.8, and 1.4+/-2.0 mm2, respectively; P&lt;0.001). The increase in peristent area was directly correlated with increases in VA. CONCLUSIONS: Both SR and MR paclitaxel-eluting stents prevent neointimal formation to the same degree compared with BMS. However, the difference in peristent remodeling suggests a release-dependent effect between SR and MR.</description>
    </item>
  </channel>
</rss>