    <item>
      <title>Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13701/</link>
      <pubDate>2005-02-22T00:00:00Z</pubDate>
      <description>BACKGROUND: The clinical impact of late incomplete stent apposition (ISA) for drug-eluting stents is unknown. We sought to prospectively investigate the incidence and extent of ISA after the procedure and at 6-month follow-up of paclitaxel-eluting stents in comparison with bare metal stents (BMS) and survey the clinical significance of ISA over a period of 12 months. METHODS AND RESULTS: TAXUS II was a randomized, double-blind study with 536 patients in 2 consecutive cohorts comparing slow-release (SR; 131 patients) and moderate-release (MR; 135 patients) paclitaxel-eluting stents with BMS (270 patients). This intravascular ultrasound (IVUS) substudy included patients who underwent serial IVUS examination after the procedure and at 6 months (BMS, 240 patients; SR, 113; MR, 116). The qualitative and quantitative analyses of ISA were performed by an independent, blinded core laboratory. More than half of the instances of ISA observed after the procedure resolved at 6 months in all groups. No difference in the incidence of late-acquired ISA was observed among the 3 groups (BMS, 5.4%; SR, 8.0%; MR, 9.5%; P=0.306), with a similar ISA volume (BMS, 11.4 mm3; SR, 21.7 mm3; MR, 8.5 mm3; P=0.18). Late-acquired ISA was the result of an increase of vessel area without change in plaque behind the stent. Predictive factors of late-acquired ISA were lesion length, unstable angina, and absence of diabetes. No stent thrombosis occurred in the patients diagnosed with ISA over a period of 12 months. CONCLUSIONS: The incidence and extent of late-acquired ISA are comparable in paclitaxel-eluting stents and BMS. ISA is a pure IVUS finding without clinical repercussions.</description>
    </item> <item>
      <title>Vascular Responses to Drug-Eluting Strents in the Prevention of Restenosis after Percutaneous Coronory Intervention (Doctoral Thesis)</title>
      <link>http://repub.eur.nl/res/pub/11366/</link>
      <pubDate>2005-02-09T00:00:00Z</pubDate>
      <description></description>
    </item> <item>
      <title>Very long sirolimus-eluting stent implantation for de novo coronary lesions. (Article)</title>
      <link>http://repub.eur.nl/res/pub/4666/</link>
      <pubDate>2004-04-01T00:00:00Z</pubDate>
      <description>Long-length stenting has a poor outcome when bare metal stents are used. The safety and efficacy of the sirolimus-eluting stent (SES) in long lesions has not been evaluated. Therefore, the aim of the present study was to evaluate the clinical and angiographic outcomes of SES implantation over a very long coronary artery segment. Since April 2002, all patients treated percutaneously at our institution received a SES as the device of choice as part of the Rapamycin Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. During the RESEARCH registry, stents were available in lengths of 8, 18, and 33 mm. The present report includes a predefined study population consisting of patients treated with &gt;36-mm-long stented segments. Patients had a combination of &gt;or=2 overlapping stents at a minimum length of 41 mm (i.e., one 33-mm SES overlapping an 8-mm SES) to treat native de novo coronary lesions. The incidence of major cardiac adverse events (death, nonfatal myocardial infarction, and target lesion revascularization) was evaluated. The study group comprised 96 consecutive patients (102 lesions). Clinical follow-up was available for all patients at a mean of 320 days (range 265 to 442). In all, 20% of long-stented lesions were chronic total occlusions, and mean stented length per lesion was 61.2 +/- 21.4 mm (range 41 to 134). Angiographic follow-up at 6 months was obtained in 67 patients (71%). Binary restenosis rate was 11.9% and in-stent late loss was 0.13 +/- 0.47 mm. At long-term follow-up (mean 320 days), there were 2 deaths (2.1%), and the overall incidence of major cardiac events was 8.3%. Thus, SES implantation appears safe and effective for de novo coronary lesions requiring multiple stent placement over a very long vessel segment.</description>
    </item> <item>
      <title>Treatment of very small vessels with 2.25-mm diameter sirolimus-eluting stents (from the RESEARCH registry). (Article)</title>
      <link>http://repub.eur.nl/res/pub/4672/</link>
      <pubDate>2004-03-01T00:00:00Z</pubDate>
      <description>A total of 91 patients with 112 lesions received 2.25-mm sirolimus-eluting stents (SESs), and these lesions were compared with those treated with SESs of ≥2.5-mm diameter in the same procedure (n = 109). The reference diameters were 1.88 ± 0.34 and 2.52 ± 0.57 mm, respectively (p &lt;0.01). At follow-up, the late lumen loss was 0.07 ± 0.48 mm for the 2.25-mm SES versus 0.03 ± 0.38 mm for the larger SES (p = 0.5), and the binary restenosis rate was 10.7% versus 3.9%, respectively (p = 0.1). The 12-month target lesion revascularization rate was 5.5%. In conclusion, 2.25-mm SESs were associated with low rates of clinical and angiographic late complications.</description>
    </item> <item>
      <title>Vascular responses at proximal and distal edges of paclitaxel-eluting stents (Article)</title>
      <link>http://repub.eur.nl/res/pub/13305/</link>
      <pubDate>2004-02-10T00:00:00Z</pubDate>
      <description>BACKGROUND: On the basis of brachytherapy experience, edge stenosis has been raised as a potential limitation for drug-eluting stents. We used serial intravascular ultrasound (IVUS) to prospectively analyze vessel responses in adjacent reference segments after implantation of polymer-controlled paclitaxel-eluting stents. METHODS AND RESULTS: TAXUS II was a randomized, double-blind trial with 2 consecutive patient cohorts that compared slow-release (SR) and moderate-release (MR) paclitaxel-eluting stents with control bare metal stents (BMS). By protocol, all patients had postprocedure and 6-month follow-up IVUS. Quantitative IVUS analysis was performed by an independent core laboratory, blinded to treatment allocation, in 5-mm vessel segments immediately proximal and distal to the stent. Serial IVUS was available for 106 SR, 107 MR, and 214 BMS patients. For all 3 groups, a significant decrease in proximal-edge lumen area was observed at 6 months. The decrease was comparable (by ANOVA, P=0.194) for patients in the SR (-0.54+/-2.1 mm2) and MR (-0.88+/-1.9 mm2) groups compared with the BMS (-1.02+/-1.9 mm2) group. For the distal edge, a significant decrease in lumen area was only observed with BMS (-0.91+/-2.0 mm2, P&lt;0.0001); this decrease was significantly attenuated with SR (0.08+/-2.0 mm2) and MR (-0.19+/-1.7 mm2) stents (P&lt;0.0001 by ANOVA). Negative vessel remodeling was observed at the proximal (-0.48+/-2.2 mm2, P=0.011) but not the distal edges of BMS and at neither edge of SR or MR stents. CONCLUSIONS: The marked reduction in in-stent restenosis with SR or MR stents is not associated with increased edge stenosis at 6-month follow-up IVUS. In fact, compared with BMS, there is instead a significant reduction in late lumen loss at the distal edge with TAXUS stents.</description>
    </item> <item>
      <title>Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13278/</link>
      <pubDate>2004-01-20T00:00:00Z</pubDate>
      <description>BACKGROUND: Polymer-controlled paclitaxel-eluting stents have shown a pronounced reduction in neointimal hyperplasia compared with bare metal stents (BMS). The aim of this substudy was to evaluate local arterial responses through the use of serial quantitative intravascular ultrasound (IVUS) analyses in the TAXUS II trial. METHODS AND RESULTS: TAXUS II was a randomized, double-blind study with 536 patients in 2 consecutive cohorts comparing slow-release (SR; 131 patients) and moderate-release (MR; 135 patients) paclitaxel-eluting stents with BMS (270 patients). This IVUS substudy included patients treated with one study stent who underwent serial IVUS examination after the procedure and at 6-month follow-up (BMS, 152 patients; SR, 81; MR, 81). The analyzed stented segment (15 mm) was divided into 5 subsegments in which mean vessel area (VA), stent area (SA), lumen area (LA), intrastent neointimal hyperplasia area (NIHA), and peristent area (VA-SA) were measured. NIHA was significantly reduced in SR (0.7+/-0.9 mm2, P&lt;0.001) and MR (0.6+/-0.8 mm2, P&lt;0.001) compared with BMS (1.9+/-1.5 mm2), with no differences between the two paclitaxel-eluting release formulations. Longitudinal distribution of neointimal hyperplasia throughout the paclitaxel-eluting stent was uniform. Neointimal growth was independent of peristent area at postprocedure examination in all groups. There were progressive increases in peristent area from BMS to SR to MR (0.5+/-1.7, 1.0+/-1.8, and 1.4+/-2.0 mm2, respectively; P&lt;0.001). The increase in peristent area was directly correlated with increases in VA. CONCLUSIONS: Both SR and MR paclitaxel-eluting stents prevent neointimal formation to the same degree compared with BMS. However, the difference in peristent remodeling suggests a release-dependent effect between SR and MR.</description>
    </item> <item>
      <title>Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world": the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13279/</link>
      <pubDate>2004-01-20T00:00:00Z</pubDate>
      <description>BACKGROUND: The effectiveness of sirolimus-eluting stents in unselected patients treated in the daily practice is currently unknown. METHODS AND RESULTS: Sirolimus-eluting stent implantation has been used as the default strategy for all percutaneous procedures in our hospital as part of the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. Consecutive patients with de novo lesions (n=508) treated exclusively with sirolimus-eluting stents (SES group) were compared with 450 patients who received bare stents in the period just before (pre-SES group). Patients in the SES group more frequently had multivessel disease, more type C lesions, received more stents, and had more bifurcation stenting. At 1 year, the cumulative rate of major adverse cardiac events (death, myocardial infarction, or target vessel revascularization) was 9.7% in the SES group and 14.8% in the pre-SES group (hazard ratio [HR], 0.62 [95% CI, 0.44 to 0.89]; P=0.008). The 1-year risk of clinically driven target vessel revascularization in the SES group and in the pre-SES group was 3.7% versus 10.9%, respectively (HR, 0.35 [95% CI, 0.21 to 0.57]; P&lt;0.001). CONCLUSIONS: Unrestricted utilization of sirolimus-eluting stents in the "real world" is safe and effective in reducing both repeat revascularization and major adverse cardiac events at 1 year compared with bare stent implantation.</description>
    </item> <item>
      <title>Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions (Article)</title>
      <link>http://repub.eur.nl/res/pub/10276/</link>
      <pubDate>2004-01-01T00:00:00Z</pubDate>
      <description>AIMS: The aim of this study is to compare the efficacy of sirolimus-eluting stents (SES) on neointimal growth and vessel remodelling for in-stent restenosis versus de novo coronary artery lesions using serial intravascular ultrasound (IVUS). METHODS AND RESULTS: The study population consisted of 86 patients with in-stent restenosis (ISR) (n=41) or de novo lesions (n=45) treated with SES and evaluated by IVUS post-procedure and at follow-up. One 18-mm SES was used for de novo lesions while 16 patients with ISR received &gt;1SES (total stented length 17.9 mm vs 22.0 mm respectively; P=0.004). At follow-up, no differences were observed between the ISR and de novo groups with respect to changes in the mean external elastic membrane (1.7% vs 1.3%; P=0.53), plaque behind the stent (1.2% vs 3.4%; P=0.49), and lumen areas (0.7% vs 1.9%; P=0.58). No positive remodelling or edge effect was observed. A gap between stents was observed in two patients with ISR, where more prominent, though non-obstructive, neointimal proliferation was noted. CONCLUSION: Sirolimus-eluting stenting is equally effective at inhibiting neointimal proliferation in de novo and ISR lesions without inducing edge restenosis or positive vascular remodelling.</description>
    </item> <item>
      <title>Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13265/</link>
      <pubDate>2003-12-02T00:00:00Z</pubDate>
      <description>BACKGROUND: Incomplete stent apposition (ISA) has been previously documented after sirolimus-eluting stent (SES) implantation. The aim of this study was to investigate the long-term intravascular ultrasound (IVUS) findings of ISA in patients who received SES. METHODS AND RESULTS: A total of 13 patients who received SES and showed ISA at follow-up IVUS (follow-up I) were investigated. IVUS was performed on all of these patients 12 months later (follow-up II). Quantitative ISA area measurement was also performed at follow-up I and II. No vascular remodeling was observed in the vessel segment with ISA; external elastic membrane area was 19.4+/-6.6 versus 19.5+/-6.4 mm2 at follow-up I and II, respectively. There was also no significant change in external elastic membrane area between vessel segment with ISA and without ISA (+1.5% versus -3.0%, respectively; P=0.27) at late follow-up. The ISA area, either including (2.5+/-1.7 versus 3.8+/-6.3 mm2; P=NS) or excluding (2.5+/-1.8 versus 2.4+/-1.7 mm2; P=NS) a single patient with aneurysm formation, was not significantly different between follow-up I and II. One patient manifested a coronary aneurysm in the stented segment at late follow-up that was probably present at the initial follow-up but masked by thrombus. It was successfully treated with a covered stent. All patients were asymptomatic, and no patient experienced late thrombotic occlusion. CONCLUSIONS: Vessel dimensions and area of ISA did not change over time, except for 1 coronary aneurysm that became apparent. ISA after implantation of a SES was not associated with adverse events at late follow-up.</description>
    </item> <item>
      <title>Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries. (Article)</title>
      <link>http://repub.eur.nl/res/pub/4699/</link>
      <pubDate>2003-12-01T00:00:00Z</pubDate>
      <description>The true 3-dimensional neointimal thickness distribution in sirolimus-eluting stents was investigated in relation to the shear stress distribution, which was obtained from computational fluid dynamics calculations. Small pits were observed between the stent struts in all patients, and a significant inverse relation between neointimal thickness and shear stress was found, indicating that deeper pits were present in the outside curve of the stented segments.</description>
    </item> <item>
      <title>Sirolimus-eluting stent implantation in ST-elevation acute myocardial infarction: a clinical and angiographic study. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13250/</link>
      <pubDate>2003-10-21T00:00:00Z</pubDate>
      <description>BACKGROUND: Sirolimus-eluting stents (SES) have recently been proven to reduce restenosis and reintervention compared with bare stents. Safety and effectiveness of SES in acute myocardial infarction remain unknown. METHODS AND RESULTS: Since April 16, 2002, a policy of routine SES implantation has been instituted in our hospital, with no clinical or anatomic restrictions, as part of the RESEARCH (Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital) registry. During 6 months of enrollment, 96 patients with ST-elevation acute myocardial infarction underwent percutaneous recanalization and SES implantation; these patients comprise the study population. The incidence of major adverse cardiac events (death, nonfatal myocardial infarction, reintervention) was evaluated. Six-month angiographic follow-up was scheduled per protocol. At baseline, diabetes mellitus was present in 12.5% and multivessel disease in 46.9%. Primary angioplasty was performed in 89 patients (92.7%). Infarct location was anterior in 41 (42.7%) of the cases, and 12 patients (12.5%) had cardiogenic shock. Postprocedural TIMI-3 flow was achieved in 93.3% of the cases. In-hospital mortality was 6.2%. One patient (1.1%) had reinfarction and target lesion reintervention the first day as a result of distal dissection and acute vessel occlusion. During follow-up (mean follow-up of 218+/-75 days), 1 patient died (1.1%), no patient had recurrent myocardial infarction, and there were no additional reinterventions. No early or late stent thromboses were documented. At angiographic follow-up (70%), late loss was -0.04+/-0.25, and no patient presented angiographic restenosis. CONCLUSIONS: In this study, sirolimus-eluting stent implantation for patients with ST-elevation acute myocardial infarction was safe without documented angiographic restenosis at 6 months.</description>
    </item> <item>
      <title>Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. (Article)</title>
      <link>http://repub.eur.nl/res/pub/13177/</link>
      <pubDate>2003-07-22T00:00:00Z</pubDate>
      <description>BACKGROUND: We describe the clinical and morphological patterns of restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS: From 121 patients with coronary angiography obtained &gt;30 days after SES implantation, restenosis (diameter stenosis &gt;50%) was identified in 19 patients and 20 lesions (located at the proximal 5-mm segment in 30% or within the stent in 70%). Residual dissection after the procedure or balloon trauma outside the stent was identified in 83% of the proximal edge lesions. Lesions within the stent were focal, and stent discontinuity was identified in some lesions evaluated by intravascular ultrasound. CONCLUSIONS: Sirolimus-eluting stent edge restenosis is frequently associated with local trauma outside the stent. In-stent restenosis occurs as a localized lesion, commonly associated with a discontinuity in stent coverage. Local conditions instead of intrinsic drug-resistance to sirolimus are likely to play a major role in post-SES restenosis.</description>
    </item> <item>
      <title>TAXUS III Trial: In-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation (Article)</title>
      <link>http://repub.eur.nl/res/pub/10088/</link>
      <pubDate>2003-02-04T00:00:00Z</pubDate>
      <description>BACKGROUND: The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). METHODS AND RESULTS: The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length &lt; or =30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent). CONCLUSIONS: Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.</description>
    </item> <item>
      <title>Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience. (Article)</title>
      <link>http://repub.eur.nl/res/pub/4744/</link>
      <pubDate>2003-01-15T00:00:00Z</pubDate>
      <description>The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions.</description>
    </item> <item>
      <title>Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) (Article)</title>
      <link>http://repub.eur.nl/res/pub/9995/</link>
      <pubDate>2002-10-08T00:00:00Z</pubDate>
      <description>BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (&lt;2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD &lt;2.36 mm; stratum II, RD 2.36 mm to 2.84 mm; stratum III, RD &gt;2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD &lt;-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P&lt;0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.</description>
    </item> <item>
      <title>Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up. (Article)</title>
      <link>http://repub.eur.nl/res/pub/4768/</link>
      <pubDate>2002-09-24T00:00:00Z</pubDate>
      <description>Background— Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up.

Methods and Results— Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 µg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent.

Conclusion— Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.</description>
    </item> <item>
      <title>Intravascular Ultrasound Findings in the Multicenter, Randomized, Double-Blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) Trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/4774/</link>
      <pubDate>2002-08-13T00:00:00Z</pubDate>
      <description>Background— The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent.

Methods and Results— In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2±5 versus 37±28 mm3) and percent of volume obstruction (1±3% versus 29±20%) at 6 months between the 2 groups was highly significant (P&lt;0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P&lt;0.05), it was not associated with any adverse clinical events at 1 year.

Conclusions— Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.</description>
    </item> <item>
      <title>Images in Cardiovascular Medicine. True three-dimensional reconstructed images showing lumen enlargement after sirolimus-eluting stent implantation (Article)</title>
      <link>http://repub.eur.nl/res/pub/10023/</link>
      <pubDate>2002-01-01T00:00:00Z</pubDate>
      <description></description>
    </item> <item>
      <title>Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/9952/</link>
      <pubDate>2002-01-01T00:00:00Z</pubDate>
      <description>BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P&lt;0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P&lt;0.05), it was not associated with any adverse clinical events at 1 year. CONCLUSIONS: Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.</description>
    </item> <item>
      <title>Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up (Article)</title>
      <link>http://repub.eur.nl/res/pub/9978/</link>
      <pubDate>2002-01-01T00:00:00Z</pubDate>
      <description>BACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS: Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 microg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. CONCLUSION: Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.</description>
    </item>