<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Meredith, I.</title>
    <link>http://repub.eur.nl/res/aut/15216/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>Impact of Overlapping newer generation drug-eluting stents on clinical and angiographic outcomes: Pooled analysis of five trials from the international Global Resolute Program (Article)</title>
      <link>http://repub.eur.nl/res/pub/39926/</link>
      <pubDate>2013-05-01T00:00:00Z</pubDate>
      <description>Background: Overlapping first generation sirolimus-and paclitaxel-eluting stents are associated with persistent inflammation, fibrin deposition and delayed endothelialisation in preclinical models, and adverse angiographic and clinical outcomes-including death and myocardial infarction (MI)-in clinical studies. Objectives: To establish as to whether there are any safety concerns with newer generation drug-eluting stents (DES). Design: Propensity score adjustment of baseline anatomical and clinical characteristics were used to compare clinical outcomes (Kaplan-Meier estimates) between patients implanted with overlapping DES (Resolute zotarolimus-eluting stent (R-ZES) or R-ZES/other DES) against no overlapping DES. Additionally, angiographic outcomes for overlapping R-ZES and everolimus-eluting stents were evaluated in the randomised RESOLUTE All-Comers Trial. Setting: Patient level data from five controlled studies of the RESOLUTE Global Clinical Program evaluating the R-ZES were pooled. Enrolment criteria were generally unrestrictive. Patients:5130 patients. Main outcome measures:2-year clinical outcomes and 13-month angiographic outcomes. Results:644 of 5130 patients (12.6%) in the RESOLUTE Global Clinical Program underwent overlapping DES implantation. Implantation of overlapping DES was associated with an increased frequency of MI and more complex/calcified lesion types at baseline. Adjusted in-hospital, 30-day and 2-year clinical outcomes indicated comparable cardiac death (2-year overlap vs non-overlap:3.0% vs 2.1%, p=0.36), major adverse cardiac events (13.3% vs 10.7%, p=0.19), target-vessel MI (3.9% vs 3.4%, p=0.40), clinically driven target vessel revascularisation (7.7% vs 6.5%, p=0.32), and definite/probable stent thrombosis (1.4% vs 0.9%, p=0.28). 13-month adjusted angiographic outcomes were comparable between overlapping and non-overlapping DES. Conclusions: Overlapping newer generation DES are safe and effective, with comparable angiographic and clinical outcomes-including repeat revascularisation-to non-overlapping DES.</description>
    </item> <item>
      <title>Clinical Outcome of Patients With and Without Diabetes Mellitus After Percutaneous Coronary Intervention With the Resolute Zotarolimus-Eluting Stent. 2-Year Results From the Prospectively Pooled Analysis of the International Global RESOLUTE Program (Article)</title>
      <link>http://repub.eur.nl/res/pub/39448/</link>
      <pubDate>2013-03-21T00:00:00Z</pubDate>
      <description>Objectives: The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) in patients with coronary artery disease and diabetes. Background: The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. Methods: We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. Results: The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p &lt; 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with non-insulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). Conclusions: The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with non-insulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Clinical Response Evaluation of the Medtronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions; NCT00248079; RESOLUTE All-comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084; A Clinical Evaluation of the Medtronic Resolute Zotarolimus-Eluting Coronary Stent System in the Treatment of De Novo Lesions in Native Coronary Arteries With a Reference Vessel Diameter of 2.25 mm to 4.2 mm; NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population; NCT00752128; The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent in De Novo Lesions in Native Coronary Arteries; NCT00927940). </description>
    </item> <item>
      <title>Vascular responses at proximal and distal edges of paclitaxel-eluting stents (Article)</title>
      <link>http://repub.eur.nl/res/pub/13305/</link>
      <pubDate>2004-02-10T00:00:00Z</pubDate>
      <description>BACKGROUND: On the basis of brachytherapy experience, edge stenosis has been raised as a potential limitation for drug-eluting stents. We used serial intravascular ultrasound (IVUS) to prospectively analyze vessel responses in adjacent reference segments after implantation of polymer-controlled paclitaxel-eluting stents. METHODS AND RESULTS: TAXUS II was a randomized, double-blind trial with 2 consecutive patient cohorts that compared slow-release (SR) and moderate-release (MR) paclitaxel-eluting stents with control bare metal stents (BMS). By protocol, all patients had postprocedure and 6-month follow-up IVUS. Quantitative IVUS analysis was performed by an independent core laboratory, blinded to treatment allocation, in 5-mm vessel segments immediately proximal and distal to the stent. Serial IVUS was available for 106 SR, 107 MR, and 214 BMS patients. For all 3 groups, a significant decrease in proximal-edge lumen area was observed at 6 months. The decrease was comparable (by ANOVA, P=0.194) for patients in the SR (-0.54+/-2.1 mm2) and MR (-0.88+/-1.9 mm2) groups compared with the BMS (-1.02+/-1.9 mm2) group. For the distal edge, a significant decrease in lumen area was only observed with BMS (-0.91+/-2.0 mm2, P&lt;0.0001); this decrease was significantly attenuated with SR (0.08+/-2.0 mm2) and MR (-0.19+/-1.7 mm2) stents (P&lt;0.0001 by ANOVA). Negative vessel remodeling was observed at the proximal (-0.48+/-2.2 mm2, P=0.011) but not the distal edges of BMS and at neither edge of SR or MR stents. CONCLUSIONS: The marked reduction in in-stent restenosis with SR or MR stents is not associated with increased edge stenosis at 6-month follow-up IVUS. In fact, compared with BMS, there is instead a significant reduction in late lumen loss at the distal edge with TAXUS stents.</description>
    </item>
  </channel>
</rss>