<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Rietbergen, B. van</title>
    <link>http://repub.eur.nl/res/aut/18111/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent "error" loads (Article)</title>
      <link>http://repub.eur.nl/res/pub/15372/</link>
      <pubDate>2004-03-01T00:00:00Z</pubDate>
      <description>Osteoporotic vertebral fractures typically have a gradual onset, frequently remain clinically undetected, and do not seem to be related to traumatic events. The osteoporotic vertebrae may therefore be expected to display a less "optimal" bone architecture, leading to an uneven load distribution over the bone material. We evaluated the trabecular load distribution in an osteoporotic and a healthy vertebra under normal daily loading by combining three recent innovations: high resolution computed tomography (microCT) of entire bones, microfinite element analyses (microFEA), and parallel supercomputers. Much to our surprise, the number of highly loaded trabeculae was not higher in the osteoporotic vertebra than in the healthy one under normal daily loads (8% and 9%, respectively). The osteoporotic trabeculae were more oriented in the longitudinal direction, compensating for effects of bone loss and ensuring adequate stiffness for normal daily loading. The increased orientation did, however, make the osteoporotic structure less resistant against collateral "error" loads. In this case, the number of overloaded trabeculae in the osteoporotic vertebra was higher than in the healthy one (13% and 4%, respectively). These results strengthen the paradigm of a strong relationship between bone morphology and external loads applied during normal daily life. They also indicate that vertebral fractures result from actions like forward flexion or lifting, loads that may not be "daily" but are normally not traumatic either. If future clinical imaging techniques would enable such high-resolution images to be obtained in vivo, the combination of microCT and microFEA would produce a powerful tool to diagnose osteoporosis.</description>
    </item> <item>
      <title>Introduction and evaluation of a gray-value voxel conversion technique (Article)</title>
      <link>http://repub.eur.nl/res/pub/15366/</link>
      <pubDate>2001-04-01T00:00:00Z</pubDate>
      <description>In micro finite element analyses (microFEA) of cancellous bone, the 3D-imaging data that the FEA-models are based on, contain a range of gray-values. In the construction of the eventual FEA-model, these gray-values are commonly thresholded. Although thresholding is successful at small voxel sizes, at larger voxel sizes there is substantial loss of trabecular connectivity. We propose a new method: the gray-value method, where the microFEA-models use the information within the 3D-imaging data directly, without prior thresholding. Our question was twofold. First, how does the gray-value method compare to both plain and mass-compensated thresholding? Second, what is the effect of element size on the results obtained with the gray-value method? We used nine microCT-scans of human vertebral cancellous bone. These were degraded to represent different resolutions, and converted into microFEA-models using plain thresholding, mass-compensated thresholding, and the gray-value method. The apparent elastic moduli of the specimens were determined using microFEA. The different methods were compared on the basis of the apparent elastic moduli, compared to those calculated for a 28 microm reference model. The results showed that the gray-value method greatly improves the results relative to other methods. The gray-value method gives accurate predictions of the apparent elastic moduli, for voxel sizes up to one trabecular thickness (Tb.Th.). For voxel sizes greater than one Tb.Th. the accuracy, although still better than for both thresholding methods, becomes increasingly worse.</description>
    </item> <item>
      <title>Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques (Article)</title>
      <link>http://repub.eur.nl/res/pub/15362/</link>
      <pubDate>1998-12-01T00:00:00Z</pubDate>
      <description>In this study, we investigate if finite element (FE) analyses of human trabecular bone architecture based on 168 microm images can provide relevant information about the bone mechanical characteristics. Three human trabecular bone samples, one taken from the femoral head, one from the iliac crest, and one from the lumbar spine, were imaged with micro-computed tomography (micro-CT) using a 28 microm resolution. After reconstruction the resolution was coarsened to 168 microm. First, all reconstructions were thresholded and directly converted to FE-models built of hexahedral elements. For the coarser resolutions of two samples, this resulted in a loss of trabecular connections and a subsequent loss of stiffness. To reduce this effect, a tetrahedral element meshing based on the marching cubes algorithm, as well as a modified hexahedron meshing, which thresholds the image such that load carrying bone mass is preserved, were employed. For each sample elastic moduli and tissue Von Mises stresses of the three different 168 microm models were compared to those from the hexahedron 28 microm model. For one sample the hexahedron meshing at 168 microm produced excellent results. For the other two samples the results obtained from the hexahedral models at 168 microm resolution were poor. Considerably better results were attained for these samples when using the mass-compensated or tetrahedron meshing techniques. We conclude that the accuracy of the FE-models at 168 microm strongly depends on the bone morphology, in particular its trabecular thickness. A substantial loss of trabecular connections during the hexahedron meshing process indicates that poor FE results will be obtained. In this case the tetrahedron or mass-compensated hexahedron meshing techniques can reduce the loss of connections and produce better results than the plain hexahedron meshing techniques.</description>
    </item> <item>
      <title>Computational strategies for iterative solutions of large fem applications employing voxel data (Article)</title>
      <link>http://repub.eur.nl/res/pub/15304/</link>
      <pubDate>1996-01-01T00:00:00Z</pubDate>
      <description>FE-models for structural solid mechanics analyses can be readily generated from computer images via a 'voxel convesion' method, whereby voxels in a two- or three-dimesional computer image are directly translated to elements in a FE-model. The fact that all elements thus generated are the same creates the possibilities for fast solution algorithm that can compensate for a large number of element. The solving methods described in this paper are based on an iterative solving algorithm in combination with a uniqueelement Element-by-Element (EBE) or with a newly developed Row-by-Row (RBR) matrix-vector multiplication strategy. With these methods it is possible to solve FE-models on the order of 105 3-D brick elements on a workstation and on the order of 106 elements on a Cray computer. The methods are demonstrated for the Boussinesq problem and for FF models that represent a porous trabecular bone structure The results show that the RBR method can be 3.2 times faster than the EBE method. It was concluded that the voxel conversion method in combination with these solving methods not only provides a powerful tool to analyse structures that can not be analysed in another way, but also that this approach can be competitive with traditional meshing and solving techniques.</description>
    </item> <item>
      <title>A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models (Article)</title>
      <link>http://repub.eur.nl/res/pub/15269/</link>
      <pubDate>1995-01-01T00:00:00Z</pubDate>
      <description>The apparent mechanical behavior of trabecular bone depends on properties at the tissue or trabecular level. Many investigators have attempted to determine trabecular tissue properties and loading. However, accuracy and applicability of all methods reported are limited. The small size of the trabeculae and a possible size effect are complicating factors when using traditional testing methods on single trabeculae. Other methods reported, using models that describe the trabecular structure, are of limited value because they consider bone as a repetitive structure in order to describe a reasonably large region of bone. The present study introduces a new finite-element method strategy that enables analysis of reasonably large regions of trabecular bone in full detail. The method uses three-dimensional serial reconstruction techniques to construct a large-scale FE model, by directly converting voxels to elements. A 5 mm cube of trabecular bone was modeled in this way, resulting in a FE model that consists of 296,679 elements. Special strategies were developed to solve the set of equations that results from the FE approach. Using this model in combination with experimental apparent data taken from the literature, the upper and lower boundaries for the tissue modulus were calculated to be 10.1 and 2.23 GPa, respectively. From the local stress and strain distributions it was concluded that the deformation mode of the trabeculae in the present cube was predominantly in bending. It was concluded that the method developed offers new perspectives for the study of trabecular bone.</description>
    </item> <item>
      <title>The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials (Article)</title>
      <link>http://repub.eur.nl/res/pub/15376/</link>
      <pubDate>1992-01-01T00:00:00Z</pubDate>
      <description>Bone resorption around hip stems is a disturbing phenomenon, although its clinical significance and its eventual effects on replacement longevity are as yet uncertain. The relationship between implant flexibility and the extent of bone loss, frequently established in clinical patient series and animal experiments, does suggest that the changes in bone morphology are an effect of stress shielding and a subsequent adaptive remodeling process. This relationship was investigated using strain-adaptive bone-remodeling theory in combination with finite element models to simulate the bone remodeling process. The effects of stem material flexibility, bone flexibility, and bone reactivity on the process and its eventual outcome were studied. Stem flexibility was also related to proximal implant/bone interface stresses. The results sustain the hypothesis that the resorptive processes are an effect of bone adaptation to stress shielding. The effects of stem flexibility are confirmed by the simulation analysis. It was also established that individual differences in bone reactivity and mechanical bone quality (density and stiffness) may account for the individual variations found in patients and animal experiments. Flexible stems reduce stress shielding and bone resorption. However, they increase proximal interface stresses. Hence, the cure against bone resorption they represent may develop into increased loosening rates because of interface debonding and micromotion. The methods presented in this paper can be used to establish optimal stem-design characteristics or check the adequacy of designs in preclinical testing procedures.</description>
    </item>
  </channel>
</rss>