View Author
artery plaque image centerline point vessel method calcification study lumen imaging bifurcation reference thickness analysis shear stress ratio result algorithm extraction accuracy plaque thickness evaluation patient stenosi variation landmark observer length noncalci angiography noncalci fied plaque branch area stenosis measure shear stress intravascular ultrasound difference table detection tomography murray ultrasound relation region wall shear stress flow ratio ivus images segmentation fl ow ratio model intravascular flow ratios calci fied plaque netherland fusion noncalci fied plaques measurement value msct images number calci calcium carotid heart error cardiovasc cross-section angle distance condition journal dataset score atherosclerosi framework diameter slice correspondence
10 Most Recent Publications
|
The influence of boundary conditions on wall shear stress distribution in patients specific coronary trees
(Article)
Giessen, A. van der Groen, H.C. Doriot, P.-A. Feyter, P.J. de Steen, A.F.W. van der Vosse, F.N. van de Wentzel, J.J. Gijsen, F.J.H. |
2011-04-07
|
|
Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: An ex vivo comparison to intravascular ultrasound
(Article)
Giessen, A. van der Toepker, M.H. Gijsen, F.J.H. Wentzel, J.J. Hoffmann, U. Donelly, P.M. Bamberg, F. Schlett, C.L. Raffle, C. Irlbeck, T. Lee, H. Walsum, T.W. van Maurovich-Horvat, P. |
2010-11-01
|
|
In vivo 3D distribution of lipid-core plaque in human coronary artery as assessed by fusion of near infrared spectroscopy-intravascular ultrasound and multislice computed tomography scan
(Article)
Wentzel, J.J. Giessen, A. van der Garg, S.A. Schultz, C.J. Mastik, F. Gijsen, F.J.H. Serruys, P.W.J.C. Steen, A.F.W. van der Regar, E.S. |
2010-11-01
|
|
3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: A feasibility study
(Article)
Giessen, A. van der Schaap, M. Steen, A.F.W. van der Wentzel, J.J. Gijsen, F.J.H. Groen, H.C. Walsum, T.W. van Mollet, N.R.A. Dijkstra, J. Vosse, F.N. van de Niessen, W.J. Feyter, P.J. de |
2010-10-01
|
|
MRI-based quantification of outflow boundary conditions for computational fluid dynamics of stenosed human carotid arteries
(Article)
Groen, H.C. Simons, L. Lugt, A. van der Wentzel, J.J. Bouwhuijsen, Q.J.A. Bosboom, E.M.H. Gijsen, F.J.H. Giessen, A. van der Vosse, F.N. van de Hofman, A. Steen, A.F.W. van der Witteman, J.C.M. |
2010-08-01
|
|
Small coronary calcifications are not detectable by 64-slice contrast enhanced computed tomography
(Article)
Giessen, A. van der Gijsen, F.J.H. Steen, A.F.W. van der Wentzel, J.J. Jairam, P.M. Walsum, T.W. van Neefjes, L. Mollet, N.R.A. Niessen, W.J. Vosse, F.N. van de Feyter, P.J. de |
2010-01-01
|
|
Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
(Article)
Schaap, M. Metz, C.T. Dikici, E. O'Donnell, T. Frenay, M. Friman, O. Hoyos, M.H. Kitslaar, P.H. Krissian, K. Kühnel, C. Luengo-Oroz, M.A. Orkisz, M. Walsum, T.W. van Smedby, O. Styner, M. Szymczak, A. Tek, H. Wang, C. Warfield, S.K. Zambal, S. Zhang, Y. Krestin, G.P. Niessen, W.J. Giessen, A. van der Weustink, A.C. Mollet, N.R.A. Bauer, C. Bogunović, H. Castro, C. Deng, X. |
2009-10-01
|
|
Coronary lumen segmentation using graph cuts and robust kernel regression
(In Book)
Schaap, M.M. Neefjes, L. Metz, C.T. Giessen, A. van der Weustink, A.C. Mollet, N.R.A. Wentzel, J.J. Walsum, T.W. van Niessen, W.J. |
2009-09-21
|
|
Coronary lumen segmentation using graph cuts and robust kernel regression.
(Article)
Schaap, M.M. Neefjes, L. Metz, C.T. Giessen, A. van der Weustink, A.C. Mollet, N.R.A. Wentzel, J.J. Walsum, T.W. van Niessen, W.J. |
2009-01-01
|
|
Averaging centerlines: Mean shift on paths
(Article)
Walsum, T.W. van Schaap, M. Metz, C.T. Giessen, A. van der Niessen, W.J. |
2008-12-01
|