<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Isola, A.A.</title>
    <link>http://repub.eur.nl/res/aut/20938/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>Coronary segmentation based motion corrected cardiac CT reconstruction (Article)</title>
      <link>http://repub.eur.nl/res/pub/26741/</link>
      <pubDate>2010-12-01T00:00:00Z</pubDate>
      <description>A method to obtain motion artifact-free reconstructed images of the coronary arteries is proposed and evaluated. The method relies on the integration of coronary motion estimation in an iterative computed tomography reconstruction technique. Coronary motion fields are derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Start and end points are provided by the user in one time-frame only. Corresponding centerline positions are used to determine the motion fields from phase to phase. Finally, dense motion fields are achieved by thin-plate-spline interpolation and are used to perform a motion-corrected iterative reconstruction of a selected region of interest, which results in an effective improvement of the reconstructed image quality. </description>
    </item> <item>
      <title>Motion compensated iterative reconstruction for cardiac X-ray tomography (Doctoral Thesis)</title>
      <link>http://repub.eur.nl/res/pub/19823/</link>
      <pubDate>2010-06-18T00:00:00Z</pubDate>
      <description>Within this Ph.D. project, three-dimensional reconstruction methods for moving objects (with a focus on the human heart) from cone-beam X-ray projections using iterative reconstruction algorithms were developed and evaluated. This project was carried in collaboration with the Digital Imaging Group of Philips Research Europe – Hamburg.

In cardiac cone-beam computed tomography (CT) a large effort is continuously dedicated to increase scanning speed in order to minimize patient or organ motion during acquisition.       In particular, motion causes severe artifacts such as blurring and streaks in tomographic images. While for a large class of applications the current scanning speed is sufficient, in cardiac CT image reconstruction improvements are still required. Whereas it is currently feasible to achieve stable image quality in the resting phases of the cardiac cycle, in the phase of fast motion data acquisition is too slow. A variety of algorithms to reduce or compensate for motion artifacts have been proposed in literature. Most of the correction methods address the calculation of consistent projection data belonging to the same motion state (gated CT reconstruction). Even if gated CT leads to better results, not only with respect to the processing time but also regarding the image quality, it is also limited in its temporal and spatial resolution due to the mechanical movement of the gantry. This can lead to motion blurring, especially in the phases of fast cardiac motion during the RR interval. A motion-compensated reconstruction method for CT can be used to improve the resolution of the reconstructed image and to suppress motion blurring. Iterative techniques are a promising approach to solve this problem, since no direct inversion methods are known for arbitrarily moving objects.

In this work, we therefore introduced motion compensation into image reconstruction. In order to determine the unknown cardiac motion, 3 different cardiac-motion estimation methodologies were implemented. Visual and quantitative assessment of the method in a number of applications, including: phantoms; cardiac CT reconstructions; Region of Interest (ROI) CT reconstructions of left and right coronaries of several clinical patients, confirmed its potential.</description>
    </item> <item>
      <title>Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT (Article)</title>
      <link>http://repub.eur.nl/res/pub/17507/</link>
      <pubDate>2009-01-01T00:00:00Z</pubDate>
      <description>A method for motion compensated iterative CT reconstruction of a cardiac region-of-interest is presented. The algorithm is an ordered subset maximum likelihood approach with spherically symmetric basis functions, and it uses an ECG for gating. Since the straightforward application of iterative methods to CT data has the drawback that a field-of-view has to be reconstructed, which covers the complete volume contributing to the absorption, region-of-interest reconstruction is applied here. Despite gating, residual object motion within the reconstructed gating window leads to motion blurring in the reconstructed image. To limit this effect, motion compensation is applied. Hereto, a gated 4D reconstruction at multiple phases is generated for the region-of-interest, and a limited set of vascular landmarks are manually annotated throughout the cardiac phases. A dense motion vector field is obtained from these landmarks by scattered data interpolation. The method is applied to two clinical data sets at strongest motion phases. Comparing the method to standard gated iterative reconstruction results shows that motion compensation strongly improved reconstruction quality.</description>
    </item>
  </channel>
</rss>