<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Wright, D.J.</title>
    <link>http://repub.eur.nl/res/aut/23938/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>An entirely subcutaneous implantable cardioverter-defibrillator (Article)</title>
      <link>http://repub.eur.nl/res/pub/20092/</link>
      <pubDate>2010-07-01T00:00:00Z</pubDate>
      <description>BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two shortterm clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation thresh old in comparison with that of the standard transvenous ICD. Then we evaluated the longterm use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (±SD) energy requirement (36.6±19.8 J vs. 11.1±8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10±1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.).</description>
    </item> <item>
      <title>Classification of traumatic brain injury for targeted therapies (Article)</title>
      <link>http://repub.eur.nl/res/pub/32361/</link>
      <pubDate>2008-07-01T00:00:00Z</pubDate>
      <description>The heterogeneity of traumatic brain injury (TBI) is considered one of the most significant barriers to finding effective therapeutic interventions. In October, 2007, the National Institute of Neurological Disorders and Stroke, with support from the Brain Injury Association of America, the Defense and Veterans Brain Injury Center, and the National Institute of Disability and Rehabilitation Research, convened a workshop to outline the steps needed to develop a reliable, efficient and valid classification system for TBI that could be used to link specific patterns of brain and neurovascular injury with appropriate therapeutic interventions. Currently, the Glasgow Coma Scale (GCS) is the primary selection criterion for inclusion in most TBI clinical trials. While the GCS is extremely useful in the clinical management and prognosis of TBI, it does not provide specific information about the pathophysiologic mechanisms which are responsible for neurological deficits and targeted by interventions. On the premise that brain injuries with similar pathoanatomic features are likely to share common pathophysiologic mechanisms, participants proposed that a new, multidimensional classification system should be developed for TBI clinical trials. It was agreed that preclinical models were vital in establishing pathophysiologic mechanisms relevant to specific pathoanatomic types of TBI and verifying that a given therapeutic approach improves outcome in these targeted TBI types. In a clinical trial, patients with the targeted pathoanatomic injury type would be selected using an initial diagnostic entry criterion, including their severity of injury. Coexisting brain injury types would be identified and multivariate prognostic modeling used for refinement of inclusion/exclusion criteria and patient stratification. Outcome assessment would utilize endpoints relevant to the targeted injury type. Advantages and disadvantages of currently available diagnostic, monitoring, and assessment tools were discussed. Recommendations were made for enhancing the utility of available or emerging tools in order to facilitate implementation of a pathoanatomic classification approach for clinical trials. </description>
    </item>
  </channel>
</rss>