scaffold month stent strut patient vessel follow-up analysis lesion diameter lumen trial study 6 months recoil serruy cohort change artery scaffold area implantation plaque serruys pw result bioresorbable segment intravascular ultrasound balloon everolimus-eluting baseline procedure device imaging angiography 12 months swets subs service abbott hyperechogenicity signi lumen area value tissue 1.1 regar e coherence tomography angiographic stenosi figure outcome ficant onuma y table cohort b trial reduction cardiol intervention ormiston bioabsorbable hospital restenosi strut core area echogenicity intravascular ultrasound 12- drug-eluting 12- month follow-up 12- month outcomes tomography polymer vessel wall method onuma difference coherence everolimu luminal calcium santa clara thuesen l
6 Most Recent Publications
|
Serial in vivo intravascular ultrasound-based echogenicity changes of everolimus-eluting bioresorbable vascular scaffold during the first 12 months after implantation: Insights from the ABSORB B trial
(Article)
Brugaletta, S. Gomez-Lara, J. Windecker, S. Smits, P.C. Bruyne, B. de Whitbourn, R. Meredith, I. Domburg, R.T. van Sihan, K. Winter, S. de Veldhof, S. Miquel-Hébert, K. Serruys, P.W.J.C. Rapoza, R. Garcia-Garcia, H.M. Ormiston, J.A. Bruining, N. Farooq, V. Geuns, R-J.M. van Thuesen, L. Dudek, D. Koolen, J. Chevalier, B. McClean, D. |
2011-12-01
|
|
Analysis of 1 year virtual histology changes in coronary plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold
(Article)
Brugaletta, S. Gomez-Lara, J. Whitbourn, R. Meredith, I. Dorange, C. Veldhof, S. Rapoza, R. Ormiston, J.A. Serruys, P.W.J.C. Garcia-Garcia, H.M. Heo, J.H. Farooq, V. Geuns, R-J.M. van Chevalier, B. Windecker, S. McClean, D. Thuesen, L. |
2011-11-24
|
|
Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de Novo Coronary Artery stenosis: 12-month clinical and imaging outcomes
(Article)
Serruys, P.W.J.C. Onuma, Y. Windecker, S. Whitbourn, R. Meredith, I. Dorange, C. Veldhof, S. Hebert, K.M. Sudhir, K. Garcia-Garcia, H.M. Ormiston, J.A. Dudek, D. Smits, P.C. Koolen, J. Chevalier, B. Bruyne, B. de Thuesen, L. McClean, D. Geuns, R-J.M. van |
2011-10-04
|
|
6-month clinical outcomes following implantation of the bioresorbable everolimus-eluting vascular scaffold in vessels smaller or larger than 2.5 mm
(Article)
Diletti, R. Onuma, Y. Chevalier, B. McClean, D. Windecker, S. Whitbourn, R. Smits, P.C. Koolen, J. Meredith, I. Li, D. Veldhof, S. Rapoza, R. Farooq, V. Garcia-Garcia, H.M. Ormiston, J.A. Serruys, P.W.J.C. Gomez-Lara, J. Brugaletta, S. Geuns, R-J.M. van Regar, E.S. Bruyne, B. de Dudek, D. Thuesen, L. |
2011-07-12
|
|
Comparison of in vivo acute stent recoil between the bioresorbable everolimus-eluting coronary scaffolds (revision 1.0 and 1.1) and the metallic everolimus-eluting stent
(Article)
Onuma, Y. Serruys, P.W.J.C. Windecker, S. Whitbourn, R. Meredith, I. Garcia-Garcia, H.M. Ormiston, J.A. Gomez, J. Bruyne, B. de Dudek, D. Thuesen, L. Smits, P. Chevalier, B. McClean, D. Koolen, J. |
2011-07-01
|
|
Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: Six-month clinical and imaging outcomes
(Article)
Serruys, P.W.J.C. Onuma, Y. Koolen, J. Windecker, S. Whitbourn, R. Meredith, I. Dorange, C. Veldhof, S. Miquel-Hébert, K. Rapoza, R. Garcia-Garcia, H.M. Ormiston, J.A. Bruyne, B. de Regar, E.S. Dudek, D. Thuesen, L. Smits, P.C. Chevalier, B. McClean, D. |
2010-11-30
|