<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Buszman, P.</title>
    <link>http://repub.eur.nl/res/aut/6893/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>The impact of patient and lesion complexity on clinical and angiographic outcomes after revascularization with zotarolimus- and everolimus-eluting stents: A substudy of the RESOLUTE all comers trial (a randomized comparison of a zotarolimus-eluting stent with an everolimus-eluting stent for percutaneous coronary intervention) (Article)</title>
      <link>http://repub.eur.nl/res/pub/33916/</link>
      <pubDate>2011-05-31T00:00:00Z</pubDate>
      <description>Objectives: The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES). Background: Clinical and angiographic outcomes of newer-generation stents have not been described among complex patients. Methods: Patients enrolled in the RESOLUTE All Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) were stratified into "complex" and "simple." Results: Of 2,292 patients, 1,520 (66.3%) were complex and treated with ZES (n = 764) or EES (n = 756). Event rates were higher among complex patients, and results did not differ between ZES and EES, regardless of complexity. At 1 year, target lesion failure was 8.9% in ZES- and 9.7% in EES-treated complex patients (p = 0.66) and 6.8% in ZES- and 5.7% in EES-treated simple patients (p = 0.55). Rates of cardiac death (1.3% vs. 2.2%, p = 0.24), target-vessel myocardial infarction (4.3% vs. 4.4%, p = 0.90), and clinically indicated target lesion revascularization (4.4% vs. 4.0%, p = 0.80) were similar for both stent types among complex patients. Definite or probable stent thrombosis occurred in 20 (1.3%) complex patients with no difference between ZES (1.7%) and EES (0.9%, p = 0.26). Angiographic follow-up showed similar results for ZES and EES in terms of in-stent percentage diameter stenosis (22.2 ± 15.4% vs. 21.4 ± 15.8%, p = 0.67) and in-segment binary restenosis (6.6% vs. 8.0%, p = 0.82) in the complex group. Conclusions: In this all-comers randomized trial, major adverse cardiovascular events were more frequent among complex than simple patients. The newer-generation ZES and EES proved to be safe and effective, regardless of complexity, with similar clinical and angiographic outcomes for both stent types through 1 year. (RESOLUTE-III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084) </description>
    </item> <item>
      <title>The prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: A substudy of the resolute all comers trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/34681/</link>
      <pubDate>2011-04-01T00:00:00Z</pubDate>
      <description>Objectives: This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. Background: The SXscore can identify patients treated with PCI who are at highest risk of adverse events. Methods: The SXscore was calculated prospectively in 2,033 of the 2,292 patients enrolled in the RESOLUTE All Comers study (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention). Clinical outcomes in terms of a patient-oriented composite endpoint (POCE) of all-cause death, myocardial infarction (MI), and repeat revascularization; the individual components of POCE; target lesion failure (TLF) (a composite of cardiac death, target-vessel MI, and clinically driven target lesion revascularization); and stent thrombosis were subsequently stratified according to SXscore tertiles: SXscoreLOW≤9 (n = 698), 9 &lt;SXscoreMID≤17 (n = 676); SXscoreHIGH&gt;17 (n = 659). Results: At 12-month follow-up, rates of POCE, MI, repeat revascularization, TLF, and the composite of death/MI were all significantly higher in patients in the highest SXscore tercile. Rates of stent thrombosis were all highest in the SXscoreHIGHtertile (p &gt; 0.05). After multivariate adjustment, the SXscore was identified as an independent predictor of POCE, MI, repeat revascularization, and TLF (p &lt; 0.05 for all). At 12-month follow-up, the SXscore, ACEF score, and Clinical SXscore had C-statistics of 0.57, 0.78, and 0.67, respectively, for mortality and of 0.62, 0.56, 0.63, respectively, for POCE. No significant between-stent differences were observed for TLF or POCE in any of the SXscore tertiles. Conclusions: The SYNTAX score is able to stratify risk amongst an all-comers population treated with PCI with second-generation drug-eluting stents (DES); however, improvements can be made with the inclusion of clinical variables. (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084) </description>
    </item> <item>
      <title>Value of age, creatinine, and ejection fraction (acef score) in assessing risk in patients undergoing percutaneous coronary interventions in the 'All-Comers' LEADERS Trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/34687/</link>
      <pubDate>2011-02-01T00:00:00Z</pubDate>
      <description>Background-The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine &gt;2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in "all-comer" patients undergoing percutaneous coronary intervention is yet unexplored. Methods and Results-The ACEF score was calculated for 1208 of the 1707 patients enrolled in the LEADERS trial. Post hoc analysis was performed by stratifying clinical outcomes at the 1-year follow-up according to ACEF score tertiles: ACEFlow≤1.0225, 1.0225&lt; ACEFmid≤1.277, and ACEFhigh&gt;1.277. At 1-year follow-up, there was a significantly lower number of patients with major adverse cardiac event-free survival in the highest tertile of the ACEF score (ACEFlow=92.1%, ACEFmid=89.5%, and ACEFhigh=86.1%; P=0.0218). Cardiac death was less frequent in ACEFlowthan in ACEFmidand ACEFhigh(0.7% vs 2.2% vs 4.5%; hazard ratio=2.22, P=0.002) patients. Rates of myocardial infarction were significantly higher in patients with a high ACEF score (6.7% for ACEFhighvs 5.2% for ACEFmidand 2.5% for ACEFlow; hazard ratio=1.6, P=0.006). Clinically driven target-vessel revascularization also tended to be higher in the ACEFhighgroup, but the difference among the 3 groups did not reach statistical significance. The rate of composite definite, possible, and probable stent thrombosis was also higher in the ACEFhighgroup (ACEFlow=1.2%, ACEFmid=3.5%, and ACEFhigh=6.2%; hazard ratio=2.04, P=0.001). Conclusions-ACEF score may be a simple way to stratify risk of events in patients treated with percutaneous coronary intervention with respect to mortality and risk of myocardial infarction. </description>
    </item> <item>
      <title>Value of the SYNTAX score for risk assessment in the all-comers population of the randomized multicenter LEADERS (limus eluted from a durable versus ERodable stent coating) trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/20963/</link>
      <pubDate>2010-07-20T00:00:00Z</pubDate>
      <description>Objectives: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. Background: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. Methods: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. Results: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore ≤8 (SXlow) (n = 464), SXscore &gt;8 and ≤16 (SXmid) (n = 472), and SXscore &gt;16 (SXhigh) (n = 461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow = 92.2%, SXmid = 91.1%, and SXhigh = 84.6%; p &lt; 0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p = 0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p = 0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p &lt; 0.001). Conclusions: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220)</description>
    </item> <item>
      <title>Comparison of zotarolimus-eluting and everolimus-eluting coronary stents (Article)</title>
      <link>http://repub.eur.nl/res/pub/20630/</link>
      <pubDate>2010-07-01T00:00:00Z</pubDate>
      <description>BACKGROUND: New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS: In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS: At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P&lt;0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P = 0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (±SD) of in-stent stenosis (21.65±14.42% for zotarolimus vs. 19.76±14.64% for everolimus, P = 0.04 for noninferiority). In-stent late lumen loss was 0.27±0.43 mm in the zotarolimus-stent group versus 0.19±0.40 mm in the everolimusstent group (P = 0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS: At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria.</description>
    </item> <item>
      <title>The Impact of Body Mass Index on the One Year Outcomes of Patients Treated by Percutaneous Coronary Intervention With Biolimus- and Sirolimus-Eluting Stents (from the LEADERS Trial) (Article)</title>
      <link>http://repub.eur.nl/res/pub/18221/</link>
      <pubDate>2010-02-15T00:00:00Z</pubDate>
      <description>The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (&lt;25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (&gt;30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.</description>
    </item> <item>
      <title>Impact of Vessel Size on Angiographic and Clinical Outcomes of Revascularization With Biolimus-Eluting Stent With Biodegradable Polymer and Sirolimus-Eluting Stent With Durable Polymer. The LEADERS Trial Substudy (Article)</title>
      <link>http://repub.eur.nl/res/pub/24413/</link>
      <pubDate>2009-09-01T00:00:00Z</pubDate>
      <description>Objectives: We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS). Background: Stenting of small vessels might be associated with higher rates of adverse events. Methods: "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter ≤2.75 mm versus &gt;2.75 mm. Results: Of 1,707 patients, 429 patients in the BES group with 576 lesions and 434 patients in the SES group with 557 lesions had only small vessels treated (50.6% of the patient cohort). In patients with small vessels there was no significant difference in overall major adverse cardiac events (MACE) rate (12.1% vs. 11.8%; p = 0.89) or target lesion revascularization (TLR) rate (9.6% vs. 7.4%; p = 0.26) between BES and SES. The MACE and TLR rates in the small-vessel patient population were higher than in the large-vessel population. The TLR rate was 9.6% versus 2.6%, and MACE rate was 12.1% versus 7.1% for small versus large vessels in the BES arm (TLR: hazard ratio [HR] = 3.724, p = 0.0013; MACE: HR = 1.720, p = 0.0412). In the SES arm, TLR was 7.4% versus 5.1%, and MACE was 11.8% versus 10.3% in small versus large vessels (TLR: HR = 1.435, p = 0.2594; MACE: HR = 1.149, p = 0.5546). Conclusions: Prevalence of small vessel disease is high in an "all-comer" population with higher TLR and MACE rates. The BES and SES seem equivalent in treatment outcomes of small vessels in this "all-comer" patient population. </description>
    </item> <item>
      <title>Effects of the direct lipoprotein-associated phospholipase A2 inhibitor darapladib on human coronary atherosclerotic plaque (Article)</title>
      <link>http://repub.eur.nl/res/pub/28817/</link>
      <pubDate>2008-09-09T00:00:00Z</pubDate>
      <description>Background - Lipoprotein-associated phospholipase A2 (Lp-PLA2) is expressed abundantly in the necrotic core of coronary lesions, and products of its enzymatic activity may contribute to inflammation and cell death, rendering plaque vulnerable to rupture. Methods and Results - This study compared the effects of 12 months of treatment with darapladib (an oral Lp-PLA2 inhibitor, 160 mg daily) or placebo on coronary atheroma deformability (intravascular ultrasound palpography) and plasma high-sensitivity C-reactive protein in 330 patients with angiographically documented coronary disease. Secondary end points included changes in necrotic core size (intravascular ultrasound radiofrequency), atheroma size (intravascular ultrasound gray scale), and blood biomarkers. Background therapy was comparable between groups, with no difference in low-density lipoprotein cholesterol at 12 months (placebo, 88±34 mg/dL; darapladib, 84±31 mg/dL; P=0.37). In contrast, Lp-PLA2 activity was inhibited by 59% with darapladib (P&lt;0.001 versus placebo). After 12 months, there were no significant differences between groups in plaque deformability (P=0.22) or plasma high-sensitivity C-reactive protein (P=0.35). In the placebo-treated group, however, necrotic core volume increased significantly (4.5±17.9 mm; P=0.009), whereas darapladib halted this increase (-0.5±13.9 mm; P=0.71), resulting in a significant treatment difference of -5.2 mm (P=0.012). These intraplaque compositional changes occurred without a significant treatment difference in total atheroma volume (P=0.95). Conclusions - Despite adherence to a high level of standard-of-care treatment, the necrotic core continued to expand among patients receiving placebo. In contrast, Lp-PLA2 inhibition with darapladib prevented necrotic core expansion, a key determinant of plaque vulnerability. These findings suggest that Lp-PLA2 inhibition may represent a novel therapeutic approach. </description>
    </item> <item>
      <title>Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial (Article)</title>
      <link>http://repub.eur.nl/res/pub/14726/</link>
      <pubDate>2008-09-01T00:00:00Z</pubDate>
      <description>Background: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). Methods: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. Findings: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0·88 [95% CI 0·64-1·19], p for non-inferiority=0·003, p for superiority=0·39). Frequency of cardiac death (14 [1·6%] vs 21 [2·5%], p for superiority=0·22), myocardial infarction (49 [5·7%] vs 39 [4·6%], p=0·30), and clinically-indicated target vessel revascularisation (38 [4·4%] vs 47 [5·5%], p=0·29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20·9% vs 23·3%, difference -2·2% [95% CI -6·0 to 1·6], p for non-inferiority=0·001, p for superiority=0·26). Interpretation: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. Funding: Biosensors Europe SA, Switzerland.</description>
    </item> <item>
      <title>Actinomycin-eluting stent for coronary revascularization: a randomized feasibility and safety study: the ACTION trial. (Article)</title>
      <link>http://repub.eur.nl/res/pub/4636/</link>
      <pubDate>2004-10-06T00:00:00Z</pubDate>
      <description>OBJECTIVES: We sought to demonstrate the safety and performance of the actinomycin D-coated Multilink-Tetra stent(Guidant Corp., Santa Clara, California) in the treatment of patients with single de novo native coronary lesions. BACKGROUND: Drug-eluting stents (DES) releasing sirolimus or paclitaxel dramatically reduce restenosis. The anti-proliferative drug, actinomycin D, which is highly effective in reducing neointimal proliferation in preclinical studies, was selected for clinical evaluation. METHODS: The multi-center, single-blind, three-arm ACTinomycin-eluting stent Improves Outcomes by reducing Neointimal hyperplasia (ACTION) trial randomized 360 patients to receive a DES (2.5 or 10 microg/cm(2) of actinomycin D) or metallic stent (MS). The primary end points were major adverse cardiac events (MACE) at 30 days, diameter stenosis by angiography, tissue effects, and neointimal volume by intravascular ultrasound (IVUS) at six months. When early monitoring revealed an increased rate of repeat revascularization, the protocol was amended to allow for additional follow-up for DES patients. Angiographic control of MS patients was no longer mandatory. RESULTS: The biased selection of DES patients undergoing IVUS follow-up invalidated the interpretation of the IVUS findings. The in-stent late lumen loss and that at the proximal and distal edges were higher in both DES groups than in the MS group and resulted in higher six-month and one-year MACE (34.8% and 43.1% vs. 13.5%), driven exclusively by target vessel revascularization without excess death or myocardial infarction. CONCLUSIONS: The results of the ACTION trial indicate that all anti-proliferative drugs will not uniformly show a drug class effect in the prevention of restenosis.</description>
    </item>
  </channel>
</rss>