<?xml version="1.0" encoding="UTF-8" standalone="no" ?>
<rss version="2.0">
  <channel>
    <title>Heuvel, P.A. van den</title>
    <link>http://repub.eur.nl/res/aut/8405/</link>
    <description>List of Publications</description>
    <language>en</language>
    <image>
      <url>http://repub.eur.nl/static-eur/img/logo.png</url>
      <title>RePub, Erasmus University Rotterdam</title>
      <link>http://repub.eur.nl</link>
    </image>
    <item>
      <title>Intravascular Ultrasound Comparison of Sirolimus-Eluting Stent Versus Bare Metal Stent Implantation in Diseased Saphenous Vein Grafts (from the RRISC [Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent] Trial) (Article)</title>
      <link>http://repub.eur.nl/res/pub/35345/</link>
      <pubDate>2007-07-01T00:00:00Z</pubDate>
      <description>The randomized Reduction of Restenosis In Saphenous Vein Grafts with Cypher Sirolimus-Eluting Stent trial compared angiographic outcomes of sirolimus-eluting stents (SESs) versus bare metal stents (BMSs) in saphenous vein grafts (SVG). Using intravascular ultrasound (IVUS) performed during 6-month follow-up angiography, we compared the vascular effects of the 2 types of stent on SVGs. Of 75 patients (96 lesions) included, 59 patients underwent IVUS in 61 SVGs; 29 patients received 40 SESs for 34 lesions, and 30 patients received 42 BMSs for 39 lesions. IVUS parameters (diameters, areas, and volumes) were compared in the 2 groups. A specific analysis was performed for overlapping SESs. Median neointimal volume was 1.3 mm3(interquartile range 0 to 13.1) in SESs versus 24.5 (7.8 to 39.5) in BMSs (p &lt;0.001). Minimal incomplete stent apposition was detected at only 3 stent edges (2 BMSs, 1 SES) next to ectatic regions of the SVG. Compared with single SESs, overlapping SESs showed significant increases in neointimal reaction, with a neointimal volume of 0.6 mm3/mm of stent (0.1 to 1.8) versus 0 (0 to 0.4) in single SESs (p = 0.03), and this phenomenon was mainly localized in overlapping SES segments, where neointimal volume per millimeter of stent was 1.1 mm3/mm (0.6 to 4.4) versus 0 (0 to 1.3) in nonoverlapping segments (p = 0.05). In conclusion, SESs effectively inhibit neointimal hyperplasia volume compared with BMSs in diseased vein grafts, without evidence of increased incomplete apposition risk. The neointimal response to overlapping SES layers seems higher than to a single SES layer. </description>
    </item> <item>
      <title>Direct stenting versus direct stenting followed by centered beta-radiation with intravascular ultrasound-guided dosimetry and long-term anti-platelet treatment: results of a randomized trial: Beta-Radiation Investigation with Direct Stenting and Galileo in Europe (BRIDGE). (Article)</title>
      <link>http://repub.eur.nl/res/pub/4648/</link>
      <pubDate>2004-08-04T00:00:00Z</pubDate>
      <description>Abstract

OBJECTIVES: We sought to assess the efficacy of vascular brachytherapy (VBT) combined with stenting for the primary prevention of restenosis.

BACKGROUND: Intravascular brachytherapy after stent implantation for de novo lesions has been abandoned for the present. We revisited this procedure by optimizing all procedural steps-the use of glycoprotein IIb/IIa blockers, direct stenting, adequate radiation coverage, avoidance of edge damage, source centering, intravascular ultrasound-guided dosimetry, and continuation of a dual anti-platelet regimen for one year.

METHODS: The Beta-Radiation Investigation with Direct stenting and Galileo in Europe (BRIDGE) study is a multicenter, randomized controlled trial evaluating the long-term efficacy of VBT with P-32 (20 Gy at 1 mm in the coronary wall) after direct stenting. The primary end point was angiographic intra-stent late loss; secondary end points were six months binary restenosis and neo-intimal hyperplasia. Patients (n = 112) with de novo lesions (2.5 to 4.0 mm in diameter up to 15 mm long) were randomized to either VBT or no-VBT.

RESULTS: At six months, intra-stent loss was 0.43 and 0.84 mm (p &lt; 0.001) in the irradiated and control groups, respectively. Intra-stent neo-intimal volume was reduced from 36 mm3 to 10 mm3. However, in the irradiated group there were six late occlusions as well as eight restenoses outside the stented and peri-stented area at the fall-off dose edges of the irradiated area. Accordingly, the target vessel revascularization and major adverse cardiac and cerebrovascular events rates at one year in the VBT group (20.4% and 25.9%, respectively) were higher than in the control group (12.1% and 17.2%, respectively).

CONCLUSIONS: Despite the optimization of pre-, peri-, and post-procedural factors and despite the relative efficacy of the brachytherapy for the prevention of the intra-stent neo-intimal hyperplasia, the clinical outcome of the irradiated group was less favorable than that of the control group.</description>
    </item>
  </channel>
</rss>