Abstract
Introduction
It is estimated that 10–30% of patients with Crohn’s disease (CD) have small bowel (SB) involvement, but the exact frequency and clinical relevance of these findings is unknown. Double-balloon enteroscopy (DBE) enables endoscopic visualization of the SB. In this study we evaluated whether DBE is a feasible technique for detection of CD localized in the SB in CD patients with clinical suspicion of SB lesions and whether these findings have clinical impact.
Methods
Retrospectively we analyzed 52 DBE procedures in 40 CD patients (16 males, mean age 40 years, mean duration of CD 15 years). Included patients had clinical suspicion of small bowel CD activity, including persistent abdominal discomfort (n = 27), iron deficiency anemia (n = 9) and/or hypomagnesemia (n = 4).
Results
Active small bowel CD was found in 24 (60%) patients, leading to a change in therapy in 18 patients (75%). After a mean follow-up of 13 months, 15 (83%) had persistent clinical improvement with a significant drop of mean CDAI from 178 to 90, after a mean follow-up of 13 months.
Conclusions
DBE is a useful diagnostic tool for the evaluation of SB lesions in CD patients. The significance of these findings is emphasized by the fact that adjustment of therapy in the majority of these patients leads to significant and sustained clinical improvement.
Similar content being viewed by others
References
Cirrillo LC, Camera L, Della Noce M, et al. Accuracy of enteroclysis in Crohn’s disease of the small bowel: retrospective study. Eur Radiol. 2000;10:1894–8.
Hara AK, Leighton JA, Heigh RI, et al. Crohn disease of the small bowel: preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy. Radiology. 2006;238:128–34.
Steinhardt HJ, Loeschke K, Kasper H, et al. European cooperative Crohn’s disease study [ECCDS]: clinical features and natural history. Digestion. 1985;31:97–108.
Cosnes J, Cattan S, Blain A, et al. Long-term evaluation of disease behavior of Crohn’s disease. Inflamm Bowel Dis. 2002;8:244–50.
Wolters FL, Russel MG, Sijbrandij J, et al. (on behalf of the European Collaborative Study Group on Inflammatory Bowel Disease (EC-IBD). Disease outcome of inflammatory bowel disease patients: General outline of a Europe-wide opulationbased 10-year clinical follow-up study. Scand J Gastroenterol (Suppl). 2006;243:46–54.
Mow WS, Lo SK, Targan SR, et al. Initial experience with wireless capsule enteroscopy in the diagnosis and management of inflammatory bowel disease. Clin Gastroenterol Hepatol. 2004;2:31–40.
Voderholzer WA, Beinhoelzl J, Rogalla P, et al. Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut. 2005;54:369–73.
Triester SL, Leighton JA, Leontiadis GI, et al. A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with nonstricturing small bowel Crohn’s disease. Am J Gastroenterol. 2006;101:954–64.
Buchman AL, Miller FH, Wallin A, et al. Videocapsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine. Am J Gastroenterol. 2004;99:2171–7.
Kornbluth A, Legnani P, Lewis BS. Video capsule endoscopy in inflammatory bowel disease. Inflamm Bowel Dis. 2004;10:278–85.
Yamamoto H, Kita H, Sunada K, et al. Clinical outcomes of double-balloon endoscopy for diagnosis and treatment of small intestinal diseases. Clin Gastroenterol Hepatol. 2004;2:1010–6.
Kita H, Yamamoto H. Double-balloon endoscopy for the diagnosis and treatment of small intestinal disease. Best Pract Res Clin Gastroenterol. 2006;20:179–94.
Oshitani N, Yukawa T, Yamagami H, et al. Evaluation of deep small bowel involvement by double-balloon enteroscopy in Crohn’s disease. Am J Gastroenterol. 2006;101:1484–9.
Seiderer J, Herrmann K, Diepolder H, et al. Double-balloon enteroscopy versus magnetic resonance enteroclysis in diagnosing small-bowel Crohn’s disease: Results of a pilot study. Scand J Gastroenterol. 2007;42:1376–85.
Mary JY, Modigliani R. (Group d’Etudes Thérapeutiques de Affections Inflammatoires du Tube Digestif (GETAID)). Development and validation of an endoscopic index of the severity for Crohn’s disease: a prospective multicentre study. Gut. 1989;30:983–9.
Costamagna G, Shah SK, Riccioni ME, et al. A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease. Gastroenterology. 2002;1234:999–1005.
Scapa E, Jacob H, Lewkowicz, et al. Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology. Am J Gastroenterol. 2002;97:2776–9.
Ell C, Remke S, May A, et al. The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding. Endoscopy. 2002;34:685–9.
Chong AK, Taylor A, Miller A, et al. Capsule endoscopy vs. push enteroscopy and enteroclysis in suspect small-bowel Crohn’s disease. Gastrointest Endosc. 2005;61:255–61.
Van Tuyl SA, van Noorden JT, Kuipers EJ, et al. Results of videocapsule endoscopy in 250 patients with suspected small bowel pathology. Dig Dis Sci. 2006;51:900–5.
Mergener K, Enns R, Brandabur JJ, et al. Complications and problems with capsule endoscopy: results from two referral centers. Gastrointest Endosc. 2003;AB57:170.
Matsumoto T, Esaki M, Moriyama T, et al. Comparison of capsule endoscopy and enteroscopy with the double-balloon method in patients with obscure bleeding and polyposis. Endoscopy. 2005;37:827–32.
Chong AK, Chin BW, Meredith CG. Clinically significant small-bowel pathology identified by double-balloon enteroscopy but missed by capsule endoscopy. Gastrointest Endosc. 2006;64:445–9.
Mehdizadeh S, Han NJ, Cheng DW, et al. Success rate of retrograde double balloon enteroscopy. Gastrointest Endosc. 2007;65:633–9.
Fukumoto A, Tanaka S, Yamamoto H, et al. Diagnosis and treatment of smallbowel stricture by double balloon endoscopy. Gastrointest Endosc. 2007;66:S108–12.
Conflict of interest statement
No conflict of interest to report, no funding received.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mensink, P.B.F., Groenen, M.J., van Buuren, H.R. et al. Double-balloon enteroscopy in Crohn’s disease patients suspected of small bowel activity: findings and clinical impact. J Gastroenterol 44, 271–276 (2009). https://doi.org/10.1007/s00535-009-0011-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00535-009-0011-4