Skip to main content
Log in

Three-dimensional reconstruction of myocardial contrast perfusion from biplane cineangiograms by means of linear programming techniques

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Summary

The assessment of coronary flow reserve from the instantaneous distribution of the contrast agent within the coronary vessels and myocardial muscle at the control state and at maximal flow has been limited by the superimposition of myocardial regions of interest in the two-dimensional images. To overcome these limitations, we are in the process of developing a three-dimensional (3D) reconstruction technique to compute the contrast distribution in cross sections of the myocardial muscle from two orthogonal cineangiograms. To limit the number of feasible solutions in the 3D-reconstruction space, the 3D-geometry of the endo- and epicardial boundaries of the myocardium must be determined. For the geometric reconstruction of the epicardium, the centerlines of the left coronary arterial tree are manually or automatically traced in the biplane views. Next, the bifurcations are detected automatically and matched in these two views, allowing a 3D-representation of the coronary tree. Finally, the circumference of the left ventricular myocardium in a selected cross section can be computed from the intersection points of this cross section with the 3D coronary tree using B-splines. For the geometric reconstruction of the left ventricular cavity, we envision to apply the elliptical approximation technique using the LV boundaries defined in the two orthogonal views, or by applying more complex 3D-reconstruction techniques including densitometry. The actual 3D-reconstruction of the contrast distribution in the myocardium is based on a linear programming technique (Transportation model) using cost coefficient matrices. Such a cost coefficient matrix must contain a maximum amount of a priori information, provided by a computer generated model and updated with actual data from the angiographic views. We have only begun to solve this complex problem. However, based on our first experimental results we expect that the linear programming approach with advanced cost coefficient matrices and computed model will lead to acceptable solutions in the 3D-reconstruction of the myocardial contrast distribution from biplane cineangiograms.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Reiber JHC. Morphologic and densitometric analysis of coronary arteries. In: Heintzen PH, ed. Progress in digital angiocardiography. Boston/Dordrecht: Martinus Nijhoff Publishers, 1987 (in press).

    Google Scholar 

  2. Gould KL, Kirkeeide RL. Assessment of stenosis severity. In: Reiber JHC, Serruys PW, eds. State of the art in quantitative coronary arteriography. Dordrecht/Boston/Lancaster: Martinus Nijhoff Publishers, 1986: 209–228.

    Google Scholar 

  3. Zijlstra F, Ommeren J van, Reiber JHC, Serruys PW. Does quantitative assessment of coronary artery dimensions predict the physiological significance of a coronary stenosis? Circ 1987; 75: 1154–1161.

    Google Scholar 

  4. Vogel R, LeFree M, Bates E, O'Neill W, Foster R, Kirkin P, Smith D, Pitt B. Applications of digital techniques to selective coronary arteriography: use of myocardial contrast appearance time to measure coronary flow reserve. Am Heart J 1984; 107: 153–164.

    PubMed  Google Scholar 

  5. Wilson RF, White CW. Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans. Circ 1986; 73: 444–451.

    PubMed  Google Scholar 

  6. Zijlstra F, Serruys PW, Hugenholtz PG. Papaverine: the ideal coronary vasodilator for investigating CFR? A study of timing magnitude, reproducibility and safety of the coronary hyperemic response after intracoronary papaverine. Cath and Cardiovasc Diagn 1986; 12: 298–303.

    Google Scholar 

  7. Ommeren J van, Zijlstra F, Serruys PW, Reiber JHC. A rapid angiographic technique to measure relative coronary blood flow. In: Young IT, Biemond J, Duin RPW, Gerbrands JJ, eds. Signal processing III: Theories and applications. Amsterdam/New York/Oxford/Tokyo: North-Holland, 1986: 1375–1378.

    Google Scholar 

  8. Dumay ACM. 3D-reconstruction from two orthogonal projections with linear programming techniques. Thesis, Information Theory Group. Delft University of Technology, June 1986 (in Dutch).

  9. Onnasch DGW. Reconstruction of the spatial distribution of myocardial perfusion from multiple-view arteriography. In: Heintzen P, ed. Progress in digital angiocardiography. Boston/Dordrecht: Martinus Nijhoff Publishers, 1987 (in press).

    Google Scholar 

  10. Slump CH, Gerbrands JJ. A network flow approach to the reconstruction of the left ventricle from two projections. Comp Graph and Im Proc 1982; 18: 18–36.

    Google Scholar 

  11. Reiber JHC, Gerbrands JJ, Troost GJ, Kooijman CJ, Slump CH. 3D-reconstruction of coronary arterial segments from two projections. In: Heintzen PH, Brennecke R, eds. Digital imaging in cardiovascular radiology. Stuttgart: Georg Thieme Verlag, 1983: 151–163.

    Google Scholar 

  12. Gerbrands JJ, Slump CH. 3D-reconstruction of homogeneous objects from two Poisson-distributed projections. Patt Recogn Letters 1985; 3: 137–145.

    Google Scholar 

  13. Wagner HM. Principles of operations research, with applications to managerial decisions. 2nd ed. London: Prentice/Hall Int, 1975.

    Google Scholar 

  14. Reiber JHC, Serruys PW, Slager CJ. Quantitative coronary and left ventricular cineangiography; methodology and clinical applications. Boston/Dordrecht/Lancaster: Martinus Nijhoff Publishers, 1986.

    Google Scholar 

  15. Reiber JHC, Zijlstra F, Ommeren J van, Serruys PW. Relation between coronary flow reserve and severity of coronary obstruction, both assessed from coronary cineangiogram. In: Heintzen PH, ed. Progress in digital angiocardiography. Dordrecht: Martinus Nijhoff Publishers, 1987 (in press).

    Google Scholar 

  16. Gerbrands JJ, Reiber JHC, Kooijman CJ, Rademaker RT. Model-guided segmentation of coronary cine-angiograms. In: Schüssler HW, ed. Signal Processing II: Theories and applications. Amsterdam/New York/Oxford/Tokyo: North-Holland, 1983: 601–604.

    Google Scholar 

  17. Langhout G. Structurele analyse van de kransslagaderboom uit röntgenfilms. Thesis, Information Theory Group, Faculty of Electrical Engineering, Delft University of Technology, May 1982 (in Dutch).

  18. Minderhoud H. Onderzoek naar en implementatie van omhullende-technieken ten behoeve van de reconstructie van het spierweefsel van de linker-hartkamer. Thesis, Information Theory Group, Faculty of Electrical Engineering, Delft University of Technology, June 1987 (in Dutch).

  19. Leeuwen PJ van, Reiber JHC. Automated detection of left ventricular boundaries from 35 mm contrast cineangiograms. In: Young IT, Biemond J, Duin RPW, Gerbrands JJ, eds. Signal processing III: Theories and applications. Amsterdam/New York/Oxford/Tokyo: North-Holland, 1986: 1409–1412.

    Google Scholar 

  20. Eiho S, Kuwahara M. 3D-reconstruction of the left ventricle. Preceedings Eight Annual Conference of the IEEE. Engineering and Biology Society, IEEE Cat no. 86CH2368-9, 1986: 112–115.

  21. Onnasch DGW, Schmitz W, Heintzen PH. Problems of the binary reconstruction of the left ventricle from biplane angiocardiograms. In: Heintzen PH, Brennecke R, eds. Digital imaging in cardiovascular radiography. Stuttgart, New York: Georg Thieme Verlag, 1983: 141–151.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dumay, A.C.M., Minderhoud, H., Gerbrands, J.J. et al. Three-dimensional reconstruction of myocardial contrast perfusion from biplane cineangiograms by means of linear programming techniques. Int J Cardiac Imag 3, 141–152 (1988). https://doi.org/10.1007/BF01814887

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01814887

Key words

Navigation