Coronary arteriography for quantitative analysis: Experimental and clinical comparison of cinefilm and video recordings

https://doi.org/10.1016/0002-8703(95)90270-8Get rights and content

Abstract

Although use of videotape for the recording of coronary angiograms continues to grow, the validity of quantitative coronary angiographic analysis of video images remains unknown. To estimate the realibility of angiographic images recorded on videotapes, experimental and clinical angiograms were recorded simultaneously on both 35 mm cinefilm and super-VHS videotape with normal images and with spatial filtering of the images (edge enhancement) on a digital cardiac imaging system. The experimental angiographic studies were performed with plexiglass blocks and stenosdis phantom of 0.5 to 3.0 mm in diameter. The clinical angiograms were recorded in 20 patients undergoing percutaneous transluminal coronary angioplasty (31 frames before and 20 frames after percutaneous transluminal coronary angioplasty). The cinefilm and corresponding videotapes were analyzed off-line with the new version of the coronrary angiography analysis system. For the experimental study, measurements of minimal luminal diameter obtained from cinefilm, normal-image videotape, and edge-enhanced videotape were compared with the true phanton diameter. In the clinical study the agrrement between measurements obtained from cinefilm and measurements from normal-image videotape and edge-enhanced videotape was examined. In the phantom series the accuracy and precision of quantitative coronary angiography measurement for cinefilm were −0.10 ± 0.08 mm, for normal-image videotape −0.11 ± 0.18 mm, and for edge-enhanced videotape − 0.10 ± 0.11 mm (mean ± SD). In the clinical series, the differences between measurements from cinefilm and normal-image videotape were 0.14 ± 0.20 mm and from cinefilm and edge-enhanced videotape 0.04 ± 0.13 mm. In the experimental phantom study, the use of cinefilm resulted in the most precise measurements. In the clinical study, edge-enhanced videotape provided the highest agreement with measurements obtained from cinefilm. These findings suggest that cinefilm is moore reliable than video as a recording medium for quantitative coronary analysis in scientific studies; however, for routine practice, videotape and edge-enhanced images may provide an acceptable alternative.

References (23)

  • H Wollschlager et al.

    Improvement of quantitative angiography by exact calculation of radiological magnification factors

    Comp Cardiol

    (1985)
  • Cited by (18)

    • Intraoperative ischemia and long-term events after minimally invasive coronary surgery

      2004, Annals of Thoracic Surgery
      Citation Excerpt :

      The projection using the most severe coronary narrowing was selected. Using the guiding catheter as a calibration standard, a caliper-assisted measurement of minimal lumen and reference diameters was performed, and the percent lumen diameter stenosis calculated [7]. Multivessel coronary disease was defined as more than 50% stenosis in one or more vessels remote from the LAD.

    View all citing articles on Scopus
    1

    Dr. Ozaki is a recipient of a grant from Takeda Medical Research (Taisha Ijo) Foundation, Japan.

    2

    Dr. Keane is a recipient of a travel grant from the Peel Medical Research Trust, United Kingdom.

    View full text