2019-12-05
Early rise in central venous pressure during a spontaneous breathing trial: A promising test to identify patients at high risk of weaning failure?
Publication
Publication
PLoS ONE , Volume 14 - Issue 12
Background The spontaneous breathing trial (SBT) assesses the risk of weaning failure by evaluating some physiological responses to the massive venous return increase imposed by discontinuing positive pressure ventilation. This trial can be very demanding for some critically ill patients, inducing excessive physical and cardiovascular stress, including muscle fatigue, heart ischemia and eventually cardiac dysfunction. Extubation failure with emergency reintubation is a serious adverse consequence of a failed weaning process. Some data suggest that as many as 50% of patients that fail weaning do so because of cardiac dysfunction. Unfortunately, monitoring cardiovascular function at the time of the SBT is complex. The aim of our study was to explore if central venous pressure (CVP) changes were related to weaning failure after starting an SBT. We hypothesized that an early rise on CVP could signal a cardiac failure when handling a massive increase on venous return following a discontinuation of positive pressure ventilation. This CVP rise could identify a subset of patients at high risk for extubation failure. Methods Two-hundred and four mechanically ventilated patients in whom an SBT was decided were subjected to a monitoring protocol that included blinded assessment of CVP at baseline, and at 2 minutes after starting the trial (CVP-test). Weaning failure was defined as reintubation within 48-hours following extubation. Comparisons between two parametric or nonparametric variables were performed with student T test or Mann Whitney U test, respectively. A logistic multivariate regression was performed to determine the predictive value on extubation failure of usual clinical variables and CVP at 2-min after starting the SBT. Results One-hundred and sixty-five patients were extubated after the SBT, 11 of whom were reintubated within 48h. Absolute CVP values at 2-minutes, and the change from baseline (dCVP) were significantly higher in patients with extubation failure as compared to those successfully weaned. dCVP was an early predictor for reintubation (OR: 1.70 [1.31,2.19], p<0.001). Conclusions An early rise in CVP after starting an SBT was associated with an increased risk of extubation failure. This might represent a warning signal not captured by usual SBT monitoring and could have relevant clinical implications.
Additional Metadata | |
---|---|
doi.org/10.1371/journal.pone.0225181, hdl.handle.net/1765/122643 | |
PLoS ONE | |
Organisation | Department of Intensive Care |
Dubo, S. (Sebastián), Valenzuela, E.D. (Emilio Daniel), Aquevedo, A. (Andrés), Jibaja, M. (Manuel), Berrutti, D. (Dolores), Labra, C. (Christian), … Castro, R. (2019). Early rise in central venous pressure during a spontaneous breathing trial: A promising test to identify patients at high risk of weaning failure?. PLoS ONE, 14(12). doi:10.1371/journal.pone.0225181 |