2020
Treatment of Urinary Urgency Incontinence Using a Rechargeable SNM System: 6-Month Results of the ARTISAN-SNM Study
Publication
Publication
The Journal of Urology , Volume 203 - Issue 1 p. 185- 192
PURPOSE: Sacral neuromodulation is a guideline recommended treatment of urinary dysfunction and fecal incontinence in patients in whom conservative treatments have failed. Historically sacral neuromodulation has been delivered using a nonrechargeable device with an average life span of 4.4 years. Surgery is required to replace the implanted neurostimulator due to battery depletion. Implantation of a long-lived implanted neurostimulator can eliminate the need for replacement surgeries, potentially reducing patient surgical risks and health care costs. The Axonics r-SNM System™ is a miniaturized, rechargeable sacral neuromodulation system designed to deliver therapy for at least 15 years. The ARTISAN-SNM (Axonics® Sacral Neuromodulation System for Urinary Urgency Incontinence Treatment) study is a pivotal study using rechargeable sacral neuromodulation therapy to treat urinary urgency incontinence. Six-month results are presented. MATERIALS AND METHODS: A total of 129 eligible patients with urinary urgency incontinence were treated. All participants were implanted with a tined lead and the rechargeable sacral neuromodulation system in a nonstaged procedure. Efficacy data were collected using a 3-day bladder diary, the validated ICIQ-OABqol (International Consultation on Incontinence Questionnaire Overactive Bladder quality of life) questionnaire and a participant satisfaction questionnaire. Therapy responders were identified as participants with a 50% or greater reduction in urinary urgency incontinence episodes compared to baseline. We performed an as-treated analysis in all implanted participants. RESULTS: At 6 months 90% of participants were therapy responders. The mean ± SE number of urinary urgency incontinence episodes per day was reduced from 5.6 ± 0.3 at baseline to 1.3 ± 0.2. Participants experienced a clinically meaningful 34-point improvement on the ICIQ-OABqol questionnaire. There were no serious device related adverse events. CONCLUSIONS: The Axonics r-SNM System is safe and effective with 90% of participants experiencing clinically and statistically significant improvements in urinary urgency incontinence symptoms.
Additional Metadata | |
---|---|
, , , , , , | |
doi.org/10.1097/JU.0000000000000458, hdl.handle.net/1765/122680 | |
The Journal of Urology | |
Organisation | Erasmus MC: University Medical Center Rotterdam |
McCrery, R. (Rebecca), Lane, F. (Felicia), Benson, K. (Kevin), Taylor, C. (Chris), Padron, O. (Osvaldo), Blok, B., … Goldman, H.B. (Howard B.). (2020). Treatment of Urinary Urgency Incontinence Using a Rechargeable SNM System: 6-Month Results of the ARTISAN-SNM Study. The Journal of Urology, 203(1), 185–192. doi:10.1097/JU.0000000000000458 |