Full-field strain measurement and fracture analysis of rat femora in compression test
Publication
Publication
Journal of Biomechanics , Volume 46 - Issue 7 p. 1282- 1292
There is a growing interest in studying the fracture behavior of bones, primarily due to the increasing societal burden of osteoporotic fractures. In addition, bone is one of the most important biological materials whose fracture behavior is not yet well understood. This is partly due to the fact that bone is a complex hierarchical material, and exhibits heterogeneous, anisotropic, and viscoelastic mechanical behavior. Understanding the fracture behavior of such a complex material requires application of a full-field strain measurement technique. Digital image correlation (DIC) is a relatively new full-field strain measurement technique that can be used for measurement of 3D surface strains during mechanical testing of different types of bones. In this study, we use the DIC technique to measure the surface strains during compression testing of two groups of rat femora. The first group of femora was harvested from young animals (12 weeks), while the second group was harvested from more mature animals (26 weeks). The surface strains are measured both in the linear range and close to the fracture. Using the measured data, we assess two strain-based fracture prediction criteria, namely equivalent strain fracture criterion and fracture limit diagram, to determine whether they can consistently predict the onset of fracture. The maximum load is measured to be 296±22 N (mean±SD) for young animals and 670±123 N for mature animals. It is shown that fracture in the vast majority of cases occurs in the area of maximum tensile strain. The equivalent strain fracture criterion predicts that the fracture occurs when the equivalent strain reaches 1.04±0.02% (average±SD) for young animals and 1.39±0.24% for mature animals. The fracture limit diagram predicts that the fracture occurs once the sum of major and minor principal surface strains reaches 0.63±0.23% for young animals and -0.63±0.30% for mature animals. Based on these numbers and consistency of the criteria with the strain values recorded at the fracture locations, it is concluded that the equivalent strain fracture criterion tends to be more consistent among the tested specimens.
Additional Metadata | |
---|---|
, , , , | |
doi.org/10.1016/j.jbiomech.2013.02.007, hdl.handle.net/1765/39503 | |
Journal of Biomechanics | |
Organisation | Erasmus MC: University Medical Center Rotterdam |
Amin Yavari, S., van der Stok, J., Weinans, H., & Zadpoor, A. A. (2013). Full-field strain measurement and fracture analysis of rat femora in compression test. Journal of Biomechanics, 46(7), 1282–1292. doi:10.1016/j.jbiomech.2013.02.007 |