1997-09-01
Osteonecrosis caused by percutaneous cerclage wiring of a tibial fracture: Case report
Publication
Publication
Journal of Trauma, Injury, Infection, and Critical Care , Volume 43 - Issue 3 p. 521- 522
| Additional Metadata | |
|---|---|
| doi.org/10.1097/00005373-199709000-00023, hdl.handle.net/1765/52248 | |
| Journal of Trauma, Injury, Infection, and Critical Care | |
| Organisation | Department of Orthopaedics |
|
van Steijn, M. J. A., & Verhaar, J. (1997). Osteonecrosis caused by percutaneous cerclage wiring of a tibial fracture: Case report. Journal of Trauma, Injury, Infection, and Critical Care, 43(3), 521–522. doi:10.1097/00005373-199709000-00023 |
|