2000-12-01
Strength of the intrinsic muscles of the hand measured with a hand-held dynamometer: Reliability in patients with ulnar and median nerve paralysis
Publication
Publication
Journal of Hand Surgery , Volume 25 B - Issue 6 p. 560- 565
The aim of this study was to assess the reliability of a technique to measure the strength of the intrinsic hand muscles. Intraclass Correlation Coefficients showed an excellent level of reliability for the comparison of muscle strength between groups of patients. However, for the results of individual patients, the calculated Standard Error of Measurements (10-16%) and the Smallest Detectable Differences for intraobserver (31-36%) and interobserver (37-52%) values indicate that only relatively large changes in strength can be confidently detected with this technique. The results of the present study were compared with those of four previous grip strength studies.
| Additional Metadata | |
|---|---|
| doi.org/10.1054/jhsb.2000.0415, hdl.handle.net/1765/54566 | |
| Journal of Hand Surgery | |
| Organisation | Department of Rehabilitation Medicine |
|
Schreuders, T., Roebroeck, M., van der Kar, T. J. M., Soeters, J., Hovius, S., & Stam, H. (2000). Strength of the intrinsic muscles of the hand measured with a hand-held dynamometer: Reliability in patients with ulnar and median nerve paralysis. Journal of Hand Surgery, 25 B(6), 560–565. doi:10.1054/jhsb.2000.0415 |
|