2016-09-01
Measurement of liver function using hepatobiliary scintigraphy improves risk assessment in patients undergoing major liver resection
Publication
Publication
HPB , Volume 18 - Issue 9 p. 773- 780
Background 99mTc-mebrofenin-hepatobiliary-scintigraphy (HBS) enables measurement of future remnant liver (FRL)-function and was implemented in our preoperative routine after calculation of the cut-off value for prediction of postoperative liver failure (LF). This study evaluates our results since the implementation of HBS. Additionally, CT-volumetric methods of FRL-assessment, standardized liver volumetry and FRL/body-weight ratio (FRL-BWR), were evaluated. Methods 163 patients who underwent major liver resection were included. Insufficient FRL-volume and/or FRL-function <2.7%/min/m2 were indications for portal vein embolization (PVE). Non-PVE patients were compared with a historical cohort (n = 55). Primary endpoints were postoperative LF and LF related mortality. Secondary endpoint was preoperative identification of patients at risk for LF using the CT-volumetric methods. Results 29/163 patients underwent PVE; 8/29 patients because of insufficient FRL-function despite sufficient FRL-volume. According to FRL-BWR and standardized liver volumetry, 16/29 and 11/29 patients, respectively, would not have undergone PVE. LF and LF related mortality were significantly reduced compared to the historical cohort. HBS appeared superior in the identification of patients with increased surgical risk compared to the CT-volumetric methods. Discussion Implementation of HBS in the preoperative work-up led to a function oriented use of PVE and was associated with a significant decrease in postoperative LF and LF related mortality.
Additional Metadata | |
---|---|
doi.org/10.1016/j.hpb.2016.06.006, hdl.handle.net/1765/96963 | |
HPB | |
Organisation | Department of Gastroenterology & Hepatology |
Cieslak, K. P., Bennink, R., de Graaf, W., van Lienden, K., Besselink, M., Busch, O., … van Gulik, T. (2016). Measurement of liver function using hepatobiliary scintigraphy improves risk assessment in patients undergoing major liver resection. HPB, 18(9), 773–780. doi:10.1016/j.hpb.2016.06.006 |