2016-11-23
The Promus Premier everolimus-eluting platinum chromium stent with durable polymer evaluated in a real world all-comer population in Rotterdam cardiology hospital (the P-SEARCH registry)
Publication
Publication
Background: A new-generation everolimus eluting platinum-chromium stent (EePCS), offering improved radial strength, radiopacity and conformability compared to everolimus-eluting cobalt-chromium stents (EeCCS), was evaluated with regard to safety and efficacy in an all-comer cohort.
Methods: A total of 1000 consecutive all-comer patients (including acute coronary syndrome, multivessel disease, calcified lesions) treated with an EePCS (Promus Premier™, Boston Scientific, Natick, Massachusetts) from May 2013 to October 2014 were compared to 1000 consecutive patients treated with an EeCCS (Xience Prime™, Abbott Vascular, Santa Clara, California) from April 2012 to May 2013. Patients were clinically followed for 1. year.
Results: Mean age was 66. ±. 12. years with diabetes in 20.7%, previous infarction in 22.7%, and ACS as the indication in 71.2% of patients. The mean number of stents per patient was 1.8. ±. 1.13. Total stented length was 35. ±. 25. mm. Lesion classification was B2/C in 73.9% of patients. At 1. year the primary endpoint of major adverse cardiac events (all-cause mortality, myocardial infarction [MI], ischemia-driven target vessel revascularization [TVR]) was reached in 11.7% in the EePCS cohort and 10.9% in the EeCCS cohort (adjusted HR 1.01 [0.77-1.33]; p = 0.95). No significant differences were noted in the individual clinical endpoints all-cause mortality (6.8% versus 6.4%), MI (2.2% versus 2.3%), and TVR (4.3% versus 3.7%) in the respective EePCS and EeCCS cohorts. Stent thrombosis occurred in 0.8% and 1.0% respectively.
Conclusions: In all-comer patients undergoing percutaneous coronary intervention, the use of EePCS was associated with similar 1-year clinical outcome as compared to EeCCS.
| Additional Metadata | |
|---|---|
| , , , , | |
| doi.org/10.1016/j.ijcard.2017.03.054, hdl.handle.net/1765/99224 | |
| International Journal of Cardiology | |
| Organisation | Erasmus MC: University Medical Center Rotterdam |
|
Lemmert, M., van Mieghem, N., van Geuns, R. J., Diletti, R., van Bommel, R., van Domburg, R., … Daemen, J. (2016). The Promus Premier everolimus-eluting platinum chromium stent with durable polymer evaluated in a real world all-comer population in Rotterdam cardiology hospital (the P-SEARCH registry). International Journal of Cardiology. doi:10.1016/j.ijcard.2017.03.054 |
|